Updated: April 19, 2022
The portal frame requires the wood structural panel to be fastened with 8d common or galvanized nails into all framing members at 3 inches on-center, and a 3-inch on-center grid of nails at the header. Anything less will not provide the wall's rated capacity.
FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR ... Los Angeles Residential Code > 6 Wall Construction > R602 Wood Wall Framing ...
Method PFH provides 48" of braced wall panel for each side of the opening where there is a portal frame. If an opening has a single PFH, it provides 48" of braced wall panel. A double PFH would provide 96" of braced wall panel.
Comparison graph of two assemblies for a 16-inch wide, 10-foot tall portal frame. With the testing complete, APA prepared and submitted code changes to both the ...
Continuous portal frame braced wall panels shall be constructed in accordance with Figure R602. 10.4. 1.1. The number of continuous portal frame panels in a single braced wall line shall not exceed four.